OUTPUT
|
| Output Volt Amp Capacity (VA) |
1050 |
| Output kVA Capacity (kVA) |
1 |
| Output Watt Capacity (Watts) |
650 |
| Power Factor |
0.6 |
| Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
| Nominal Voltage Details |
230V default (voltage selection via back panel switches) |
| Frequency Compatibility |
50 / 60 Hz |
| Output Voltage Regulation (Line Mode) |
-9%, +5% |
| Output Voltage Regulation (Battery Mode) |
+/- 5% |
| Output Receptacles |
(8) C13 |
| Included Output Power Cables |
Includes 2 C13 to C14 output power cables |
| Hot-Swap PDU options |
PDUBHV10 (2U / 8 C13 outlets) |
| Output AC Waveform (AC Mode) |
Sine wave |
| Output AC Waveform (Battery Mode) |
Pure Sine wave |
|
INPUT
|
| Rated input current (Maximum Load) |
2.8A (230V), 3.0A (220V), 2.7A (240V) |
| Nominal Input Voltage(s) Supported |
220V AC; 230V AC; 240V AC |
| UPS Input Connection Type |
C14 inlet |
| UPS Input Connection Description |
IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles |
| Input Phase |
Single-Phase |
|
BATTERY
|
| Full Load Runtime (min.) |
7 min. (650w) |
| Half Load Runtime (min.) |
20 min. (325w) |
| DC System Voltage (VDC) |
24 |
| Battery Recharge Rate (Included Batteries) |
Less than 8 hours from 10% to 90% (typical, full load discharge) |
| Internal UPS Replacement Battery Cartridge |
RBC24-SLT |
| Battery Access |
Battery access door |
| Battery Replacement Description |
Hot-swappable, user replaceable batteries |
| Expandable Runtime |
No |
|
VOLTAGE REGULATION
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 182 to 278 (230v), 190 to 290 (240v), 174 to 266 (220v) |
| Overvoltage Correction |
Voltage reduction of 12% applies when input is 244 to 278 (230v), 254 to 290 (240v), 232 to 266 (220v) |
| Undervoltage Correction |
Voltage boost of 14% applies when input is 182 to 206 (230v), 190 to 216 (240v), 174 to 198 (220) |
|
USER INTERFACE, ALERTS & CONTROLS
|
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection |
| Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm |
Audible alarm indicates power failure and overload conditions |
| LED Indicators |
9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level |
|
SURGE / NOISE SUPPRESSION
|
| UPS AC Suppression Joule Rating |
350 |
| UPS AC Suppression Response Time |
Instantaneous |
| UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| EMI / RFI AC Noise Suppression |
Yes |
|
PHYSICAL
|
| Primary Form Factor |
Tower |
| UPS Power Module Dimensions (hwd, cm) |
26 x 17.1 x 33.7 |
| UPS Power Module Weight (kg) |
16.3 |
| UPS Shipping Dimensions (hwd / cm) |
35.6 x 24.8 x 47 |
| Shipping Weight (kg) |
17.5 |
| Cooling Method |
Fan |
| UPS Housing Material |
Steel |
|
ENVIRONMENTAL
|
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity |
0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) |
141.1 |
| Battery Mode BTU / Hr. (Full Load) |
359.8 |
| AC Mode Efficiency Rating (100% Load) |
94% |
| Audible Noise |
Audible Noise < 50 dBA at Front Side 1 Meter |
|
COMMUNICATIONS
|
| Communications Interface |
USB; DB9 Serial; Slot for SNMP/Web interface |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software |
Included |
| Communications Cable |
USB and DB9 cabling included |
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
LINE / BATTERY TRANSFER
|
| Transfer Time |
4-8 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) |
174V (220V), 182V (230V) or 190V (240V) |
| High Voltage Transfer to Battery Power (Setpoint) |
266V (220V), 278V (230V) or 290V (240V) |
|
SPECIAL FEATURES
|
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| High Availability UPS Features |
Hot swappable batteries |
|
CERTIFICATIONS
|
| UPS Certifications |
CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Meets FCC Part 15 Category B (EMI) |
| UPS Certification Details |
CE / IEC 62040 |
|
WARRANTY
|
| Product Warranty Period (International) |
2-year limited warranty |
| Product Warranty Period (Mexico) |
2-year limited warranty |
| Product Warranty Period (Puerto Rico) |
2-year limited warranty |
|