OUTPUT
|
Output Volt Amp Capacity (VA) |
2200 |
Output kVA Capacity (kVA) |
2.2 |
Output Watt Capacity (Watts) |
1600 |
Output kW Capacity (kW) |
1.6 |
Power Factor |
0.7 |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Nominal Voltage Details |
230v inverter nominal output voltage |
Frequency Compatibility |
50 / 60 Hz |
Output Voltage Regulation (Line Mode) |
-19% +8% |
Output Voltage Regulation (Battery Mode) |
+/- 5% |
Output Receptacles |
(8) C13; (1) C19 |
Included Output Power Cables |
Includes 3 C13 to C14 output power cables |
Load Management Receptacles |
Three switchable two-outlet C13 load banks |
Output Circuit Breakers |
10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered |
Hot-Swap PDU options |
PDUBHV20 (2U / 6 C13, 2 C19 outlets) |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
PWM sine wave |
|
INPUT
|
Rated input current (Maximum Load) |
11.3A |
Nominal Input Voltage(s) Supported |
230V AC |
UPS Input Connection Type |
C20 inlet |
UPS Input Connection Description |
IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles |
Input Phase |
Single-Phase |
|
BATTERY
|
Full Load Runtime (min.) |
7 min. (1600w) |
Half Load Runtime (min.) |
19 min. (800w) |
DC System Voltage (VDC) |
48 |
Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge |
RBC54 |
Battery Access |
Battery access door |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
No |
|
VOLTAGE REGULATION
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V |
Overvoltage Correction |
Input voltages between 245 and 282 are reduced by 12% |
Undervoltage Correction |
Input voltages between 177 and 199 are boosted by 14% |
Severe Undervoltage Correction |
Input voltages between 151 and 176 are boosted by 30% |
|
USER INTERFACE, ALERTS & CONTROLS
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
|
SURGE / NOISE SUPPRESSION
|
UPS AC Suppression Joule Rating |
480 |
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
|
PHYSICAL
|
Primary Form Factor |
Tower |
UPS Power Module Dimensions (hwd, cm) |
36.2 x 23.5 x 30.5 |
UPS Power Module Weight (kg) |
24.5 |
UPS Shipping Dimensions (hwd / cm) |
40.6 x 37.5 x 50.2 |
Shipping Weight (kg) |
27.5 |
Cooling Method |
Fan |
UPS Housing Material |
Polycarbonate |
|
ENVIRONMENTAL
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
347.2 |
Battery Mode BTU / Hr. (Full Load) |
812.9 |
AC Mode Efficiency Rating (100% Load) |
94% |
Audible Noise |
Audible Noise < 47dBA At Front Side 1 Meter |
|
COMMUNICATIONS
|
Communications Interface |
USB; DB9 Serial; Contact closure |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total) |
PowerAlert Software |
Included |
Communications Cable |
2 USB and 2 DB9 cables included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
LINE / BATTERY TRANSFER
|
Transfer Time |
2-4 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) |
151 |
High Voltage Transfer to Battery Power (Setpoint) |
282 |
|
SPECIAL FEATURES
|
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Hot swappable batteries |
Green Energy-Saving Features |
Individually controllable load banks |
|
CERTIFICATIONS
|
UPS Certifications |
CE; Meets FCC Part 15 Category A (EMI) |
UPS Certification Details |
CE 62040 |
|
WARRANTY
|
Product Warranty Period (International) |
2-year limited warranty |
Product Warranty Period (Mexico) |
2-year limited warranty |
Product Warranty Period (Puerto Rico) |
2-year limited warranty |
|