OVERVIEW
|
|
OUTPUT
|
Outlet Level Metering |
Yes |
Output Capacity Details |
11.5kW (415/240V), 11.1kW (400/230V), 10.5kW (380/220V) total capacity; 16A max per output phase (L1-L2, L2-L3, L3-L1); 16A max per C19 outlet; 12A max (10A CE) max per C13 outlet |
Frequency Compatibility |
50 / 60 Hz |
Output Receptacles |
(42) C13; (6) C19 |
Output Nominal Voltage |
220 (380V input); 230 (400V input); 240 (415V input) |
Overload Protection |
n/a |
Outlet Type |
IEC-C13, IEC-C19 |
Individual Outlet Switching |
No |
|
INPUT
|
PDU Input Voltage |
380; 400; 415 |
Recommended Electrical Service |
16A 400/230V with IEC309 16A Red (3P+N+E) outlet; 20A 415/240V with IEC309 20A Red (3P+N+E) outlet |
Maximum Input Amps |
16 |
PDU Plug Type |
IEC-309 16/20A RED (3P+N+E) |
Input Cord Length (m) |
1.8 |
Input Phase |
3-Phase |
|
USER INTERFACE, ALERTS & CONTROLS
|
Reported Load Segments |
Supports local monitoring of current for each input phase (L1, L2 and L3) and output current for each output load bank (16A balanced max per B1, B2 and B3); Outlets are color-coded and labelled for phase and load bank identification; L1-N feeds black outlets (B1); L2-N feeds dark-gray outlets (B2); L3-N feeds light-gray outlets (B3) |
Front Panel LCD Display |
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature* and Humidity* information (*requires ENIVIROSENSE option); Small digital display provides detail on the measurement the large display is reporting: Input-phase (L#), Load bank (B#), Sensor (S#), Load unbalance (UB), Output power (OP) |
Front Panel LEDs |
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH); One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80% load), YELLOW (>80% load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip) |
Switches |
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options; Additional MODE button |
|
PHYSICAL
|
Shipping Dimensions (hwd / cm) |
17.5 x 24.6 x 192.8 |
Shipping Weight (kg) |
9.2 |
Unit Dimensions (hwd / cm) |
177.8 x 5.51 x 7.3 |
Unit Weight (kg) |
6.1 |
Material of Construction |
Metal |
Form Factors Supported |
Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks |
PDU Form Factor |
Vertical (0U) |
|
ENVIRONMENTAL
|
Operating Temperature Range |
32 to 122F (0 to 50C) |
Storage Temperature Range |
5 to 140F (-15C to 60C) |
Relative Humidity |
5 to 95% non-condensing |
Operating Elevation (m) |
0-3000 |
|
CERTIFICATIONS
|
Certifications |
Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), CE (EN 60950-1), CE / FCC Class A (Emissions), RoHS (Hazardous Substances), TAA Compliant |
|
WARRANTY
|
Product Warranty Period (Worldwide) |
2-year limited warranty |
|