OVERVIEW
|
|
|
OUTPUT
|
| Outlet Level Metering |
No |
| Output Capacity Details |
11.5kW (415/240V), 11.1kW (400/230V), 10.5kW (380/220V) total capacity; 16A max per output phase (L1-L2, L2-L3, L3-L1); 16A max per C19 outlet; 10A max per C13 outlet |
| Frequency Compatibility |
50 / 60 Hz |
| Output Receptacles |
(30) C13; (6) C19 |
| Output Nominal Voltage |
220 (380V input); 230 (400V input) |
| Overload Protection |
n/a |
| Outlet Type |
IEC-C13, IEC-C19 |
| Individual Outlet Switching |
No |
|
INPUT
|
| PDU Input Voltage |
380; 400 |
| Recommended Electrical Service |
16A 400/230V with IEC309 16A Red (3P+N+E) outlet |
| Maximum Input Amps |
16 |
| PDU Plug Type |
IEC-309 16/20A RED (3P+N+E) |
| Input Cord Length (m) |
3.05 |
| Input Phase |
3-Phase |
|
USER INTERFACE, ALERTS & CONTROLS
|
| Reported Load Segments |
Supports local monitoring of current for each output phase (16A balanced max per output load banks L1, L2 and L3); BANK "L1" is powered by L1-N (outlets 1-12); BANK "L2" is powered by L2-N (outlets 13-24); BANK "L3" is powered by L3-N (outlets 25-36) |
| Front Panel LCD Display |
Digital display reports output load level in amps separately for each output phase; Can also be used to scroll the configured IP address |
| Front Panel LEDs |
Set of 3 LEDs (L1, L2, L3) indicate the output load segment the digital current display is reporting |
| Switches |
SELECT switch advances the digital display and LED to report power consumption for load segments L1, L2 and L3 (short press); SELECT switch also rotates the local display 90 degrees for overhead power input (long press); SCROLL IP button scrolls the configured IP address (long press) |
|
PHYSICAL
|
| Shipping Dimensions (hwd / cm) |
18.3 x 24.5 x 192.8 |
| Shipping Weight (kg) |
9 |
| Unit Dimensions (hwd / cm) |
177.8 x 5.6 x 9.1 |
| Unit Weight (kg) |
5.7 |
| Material of Construction |
Metal |
| Form Factors Supported |
Vertical rackmount installation supported with included mounting brackets; supports tooless mounting in button-mount compatible racks |
| PDU Form Factor |
Vertical (0U) |
|
ENVIRONMENTAL
|
| Storage Temperature Range |
5 to 122F (-15 to 50C) |
| Relative Humidity |
5 to 95% non-condensing |
| Operating Elevation (m) |
0-3000 |
|
CERTIFICATIONS
|
| TAA Compliant Option |
TAA Compliant Version Available - Order Tripp Lite PDU3XVN10G16TAA |
| Certifications |
Tested to CE (EN 60950-1), Class A (Emissions), RoHS (Hazardous Substances) |
|
WARRANTY
|
| Product Warranty Period (Worldwide) |
2-year limited warranty |
|