OUTPUT
|
Output Volt Amp Capacity (VA) |
350 |
Output Watt Capacity (Watts) |
225 |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Nominal Voltage Details |
230v nominal inverter output voltage |
Frequency Compatibility |
50 / 60 Hz |
Frequency Compatibility Details |
Automatic frequency selection |
Output Voltage Regulation (Line Mode) |
-18%, +8% |
Output Receptacles |
(6) C13 |
Output AC Waveform (Battery Mode) |
PWM sine wave |
|
INPUT
|
Rated input current (Maximum Load) |
1.8A |
Nominal Input Voltage(s) Supported |
230V AC |
UPS Input Connection Type |
C14 inlet |
UPS Input Connection Description |
C14 inlet accepts user-supplied AC power cord with grounded country-specific plug |
UPS Input Cord Length (ft.) |
6 inch dongle, 16 gauge |
UPS Input Cord Length (m) |
1.83 |
Recommended Electrical Service |
10A 230V |
Voltage Compatibility (VAC) |
230 |
Input Phase |
Single-Phase |
|
BATTERY
|
Full Load Runtime (min.) |
15.5 min. (225w) |
Half Load Runtime (min.) |
37 min. (115w) |
DC System Voltage (VDC) |
12 |
Battery Recharge Rate (Included Batteries) |
Less than 7.2 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge |
RBC52(quantity 2) |
Battery Access |
Battery access door allows hot-swap battery replacement without powering connected equipment off |
Typical Battery Lifespan |
3-6 years, depending on usage |
Expandable Runtime |
No |
|
VOLTAGE REGULATION
|
Voltage Regulation Description |
Line interactive UPS offers a single boost level of brownout correction to maintain usable, computer grade output |
Undervoltage Correction |
Input voltages between 159 and 199 are boosted by 14% |
|
USER INTERFACE, ALERTS & CONTROLS
|
Switches |
Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions |
Audible Alarm |
Audible alarm indicates power failure conditions, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain (assuming full load) |
LED Indicators |
4 LEDs indicate line power, battery power, overload and battery low/replace status |
|
SURGE / NOISE SUPPRESSION
|
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Response Time |
Instantaneous |
Dataline Suppression |
2-Line Tel/DSL |
|
PHYSICAL
|
Installation Form Factors Supported with Included Accessories |
Tower |
Installation Form Factors Supported with Optional Accessories |
Wallmount(UPSWM - tower mounting kit) |
Primary Form Factor |
Tower |
UPS Power Module Dimensions (hwd, cm) |
26.9 x 13.1 x 18.8 |
UPS Power Module Weight (kg) |
11.5 |
UPS Shipping Dimensions (hwd / cm) |
35.9 x 26.5 x 20.9 |
Shipping Weight (kg) |
12.3 |
Cooling Method |
Convection |
UPS Housing Material |
PVC |
|
ENVIRONMENTAL
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
15.6 |
Battery Mode BTU / Hr. (Full Load) |
124.5 |
|
COMMUNICATIONS
|
Communications Interface |
USB |
|
LINE / BATTERY TRANSFER
|
Transfer Time |
5 milliseconds AC to battery; 8 milliseconds battery to AC |
Low Voltage Transfer to Battery Power (Setpoint) |
159 |
High Voltage Transfer to Battery Power (Setpoint) |
266 |
|
SPECIAL FEATURES
|
Grounding Lug |
Ground Potential Equalization Connector: POAG-S6/20 |
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
|
CERTIFICATIONS
|
UPS Certifications |
CE; Tested to UL60601-1 (medical grade) |
Certifications |
Tested to CE/ IEC 60601-1 (Series AGOM6832), Class B (emissions) |
|
WARRANTY
|
Product Warranty Period (International) |
2-year limited warranty |
Product Warranty Period (Mexico) |
2-year limited warranty |
Product Warranty Period (Puerto Rico) |
2-year limited warranty |
|