OUTPUT
|
Output Volt Amp Capacity (VA) |
1000 |
Output Watt Capacity (Watts) |
500 |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Nominal Voltage Details |
230V inverter nominal voltage output |
Frequency Compatibility |
50 / 60 Hz |
Output Voltage Regulation (Battery Mode) |
+/- 5% |
Output Receptacles |
(6) C13 |
Included Output Power Cables |
Includes 2 C13 to C14 output power cables |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
PWM sine wave |
|
INPUT
|
Rated input current (Maximum Load) |
2.4A |
Nominal Input Voltage(s) Supported |
230V AC |
UPS Input Connection Type |
C14 inlet |
UPS Input Connection Description |
Attached 15cm line cord with C14 inlet. The C14 inlet accepts a user-supplied AC power cord with country specific plug. |
UPS Input Cord Length (ft.) |
0.5 |
UPS Input Cord Length (m) |
0.2 |
Input Phase |
Single-Phase |
|
BATTERY
|
Full Load Runtime (min.) |
5 min. (500w) |
Half Load Runtime (min.) |
12 min. (250w) |
DC System Voltage (VDC) |
12 |
Battery Recharge Rate (Included Batteries) |
Less than 9 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge |
RBC51 |
Battery Access |
Battery access door |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
No |
|
VOLTAGE REGULATION
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 159 |
Undervoltage Correction |
Input voltages between 159 and 199 are boosted by 14% |
|
USER INTERFACE, ALERTS & CONTROLS
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Audible Alarm |
Audible alarm indicates power-failure and low-battery conditions |
LED Indicators |
4 LEDs indicate line power, battery power, overload and battery low/replace status |
|
SURGE / NOISE SUPPRESSION
|
UPS AC Suppression Joule Rating |
508 |
UPS AC Suppression Response Time |
Instantaneous |
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out) |
EMI / RFI AC Noise Suppression |
Yes |
|
PHYSICAL
|
Installation Form Factors Supported with Included Accessories |
Tower |
Installation Form Factors Supported with Optional Accessories |
Wallmount(UPSWM - tower mounting kit) |
Primary Form Factor |
Tower |
UPS Power Module Dimensions (hwd, cm) |
27.3 x 13.3 x 19 |
UPS Power Module Weight (kg) |
7.6 |
UPS Shipping Dimensions (hwd / cm) |
35.6 x 21.6 x 27.9 |
Shipping Weight (kg) |
8.9 |
UPS Housing Material |
PVC |
|
ENVIRONMENTAL
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
147.8 |
Battery Mode BTU / Hr. (Full Load) |
254 |
AC Mode Efficiency Rating (100% Load) |
92% |
|
COMMUNICATIONS
|
Communications Interface |
USB |
PowerAlert Software |
Free download from www.tripplite.com |
Communications Cable |
USB interface cable included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
LINE / BATTERY TRANSFER
|
Transfer Time |
4 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) |
159 |
High Voltage Transfer to Battery Power (Setpoint) |
Yes |
|
SPECIAL FEATURES
|
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Hot swappable batteries |
|
CERTIFICATIONS
|
UPS Certifications |
CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina); Meets FCC Part 15 Category B (EMI) |
UPS Certification Details |
CE IEC62040 |
|
WARRANTY
|
Product Warranty Period (International) |
2-year limited warranty |
Product Warranty Period (Mexico) |
2-year limited warranty |
Product Warranty Period (Puerto Rico) |
2-year limited warranty |
|