OUTPUT
|
| Output Volt Amp Capacity (VA) |
3000 |
| Output kVA Capacity (kVA) |
3 |
| Output Watt Capacity (Watts) |
2250 |
| Output kW Capacity (kW) |
2.25 |
| Output Capacity Details |
2250W maximum with up to 1 external battery pack; 1500W maximum with 2 or more external battery packs |
| Power Factor |
0.75 |
| Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
| Nominal Voltage Details |
230v nominal inverter output voltage |
| Frequency Compatibility |
50 / 60 Hz |
| Output Voltage Regulation (Line Mode) |
-19% +8% |
| Output Voltage Regulation (Battery Mode) |
+/- 5% |
| Output Receptacles |
(8) C13; (1) C19 |
| Included Output Power Cables |
Includes 3 C13 to C14 output power cables |
| Load Management Receptacles |
Three switchable two-outlet C13 load banks |
| Output Circuit Breakers |
10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered |
| Output AC Waveform (AC Mode) |
Sine wave |
| Output AC Waveform (Battery Mode) |
PWM sine wave |
|
INPUT
|
| Rated input current (Maximum Load) |
15.4A |
| Nominal Input Voltage(s) Supported |
230V AC |
| UPS Input Connection Type |
C20 inlet |
| UPS Input Connection Description |
User supplies input cabling with C19 output connection |
| Input Phase |
Single-Phase |
|
BATTERY
|
| Full Load Runtime (min.) |
4 min. (2250w) |
| Half Load Runtime (min.) |
14 min. (1125w) |
| Expandable Battery Runtime |
Extended runtime supported via optional external battery packs |
| External Battery Pack Compatibility |
BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible) |
| DC System Voltage (VDC) |
48 |
| Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
| Internal UPS Replacement Battery Cartridge |
RBC54 |
| Battery Access |
Battery access door |
| Battery Replacement Description |
Hot-swappable, user replaceable batteries |
| Expandable Runtime |
Yes |
|
VOLTAGE REGULATION
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V |
| Overvoltage Correction |
Input voltages between 245 and 282 are reduced by 12% |
| Undervoltage Correction |
Input voltages between 177 and 199 are boosted by 14% |
| Severe Undervoltage Correction |
Input voltages between 151 and 176 are boosted by 30% |
|
USER INTERFACE, ALERTS & CONTROLS
|
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
|
SURGE / NOISE SUPPRESSION
|
| UPS AC Suppression Joule Rating |
480 |
| UPS AC Suppression Response Time |
Instantaneous |
| EMI / RFI AC Noise Suppression |
Yes |
|
PHYSICAL
|
| Primary Form Factor |
Tower |
| UPS Power Module Dimensions (hwd, cm) |
36.2 x 23.5 x 30.5 |
| UPS Power Module Weight (kg) |
27.7 |
| UPS Shipping Dimensions (hwd / cm) |
40.6 x 37.5 x 50.2 |
| Shipping Weight (kg) |
30.6 |
| Cooling Method |
Fan |
| UPS Housing Material |
Polycarbonate |
|
ENVIRONMENTAL
|
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity |
0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) |
488.3 |
| AC Mode Efficiency Rating (100% Load) |
94% |
| Audible Noise |
Audible Noise < 47dBA At Front Side 1 Meter |
|
COMMUNICATIONS
|
| Communications Interface |
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software |
Included |
| Communications Cable |
2 USB and 2 DB9 cables included |
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
LINE / BATTERY TRANSFER
|
| Transfer Time |
2-4 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) |
151 |
| High Voltage Transfer to Battery Power (Setpoint) |
282 |
|
SPECIAL FEATURES
|
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| High Availability UPS Features |
Hot swappable batteries |
| Green Energy-Saving Features |
Individually controllable load banks |
|
CERTIFICATIONS
|
| UPS Certifications |
CE |
| UPS Certification Details |
CE 62040 |
|
WARRANTY
|
| Product Warranty Period (International) |
2-year limited warranty |
| Product Warranty Period (Mexico) |
2-year limited warranty |
| Product Warranty Period (Puerto Rico) |
2-year limited warranty |
|