PLEASE NOTE: All prices are exclusive of GST │ Please call / email our sales team to get the updated product price and to check the stock availability before placing an order. If you do not find the product that you require or the prices are not available ($0) please send us an email/ call us so we can assist. *Sold out products can be made available upon request.
Cart 0
Tripplite SU20KX SmartOnline 20kVA 16kW Modular 3-Phase UPS System, Double-Conversion UPS, SNMPWEBCARD Option, DB9 Serial

TrippLite

Tripplite SU20KX SmartOnline 20kVA 16kW Modular 3-Phase UPS System, Double-Conversion UPS, SNMPWEBCARD Option, DB9 Serial


Please call/ send us an email to confirm the product price and shipping cost.
sales@testequipment.co.nz │0221 (TEST NZ) 8378 69
  • 20,000 VA(20kVA) 3-phase tower UPS
  • 1+1 parallel capability allows for system redundancy or increased capacity
  • Low THDi reduces installation costs by permitting 1:1 generator sizing
  • 3-phase hardwire(220/380V, 230/400V or 240/415V AC, 3-phase, 4-wire + ground, wye) input/output
  • IGBT technology and zero transfer time, on-line, double-conversion operation
  • Runtime is expandable with the addition of two SURBC2030 internal battery packs or via external battery cabinet options

Features

  • 1+1 configuration: Two SU20KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
  • Low THDi(less than 3%) reduces installation costs by allowing 1:1 generator sizing
  • Extremely efficient operation(up to 97%) saves money by reducing electricity consumption
  • True on-line, double-conversion UPS with IGBT technology provides pure sine wave AC output at all times
  • Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
  • Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
  • 20,000VA/16,000W power capacity with 3-phase, hardwire input/output connections
  • Wide input voltage correction range: 173-276V/300-477V AC
  • Precision +/-1% output voltage regulation
  • Internal power and battery modules are combined in a single small-footprint tower compartment. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules(Models BP480V26B and BP480V40C, available separately)
  • Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
  • Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
  • Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server
  • Accessory slot accepts an optional internal SNMP card(ModelSNMPWEBCARD) for remote shutdowns, reboots and more
  • Emergency Power Off button turns UPS output OFF and disables Bypass output
  • Built-in Emergency Power Off(EPO) dry-contact interface supports remote emergency shutdown in large facilities
Electrical Contracting Products Innovation Awards Finalist

Specifications

OUTPUT
Output Volt Amp Capacity (VA) 20000
Output kVA Capacity (kVA) 20
Output Watt Capacity (Watts) 16000
Output kW Capacity (kW) 16
Power Factor 0.8
Crest Factor 3:1
Nominal Output Voltage(s) Supported 220/380V; 230/400V; 240/415V; 3-Phase Wye
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode) +/-1%
Output Voltage Regulation (Battery Mode) +/-1%
Output Receptacles Hardwire
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 28A / 29A / 30A
Nominal Input Voltage(s) Supported 220/380V (3ph wye); 230/400V (3ph wye); 240/415V (3ph wye)
Nominal Input Voltage Description 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS Input Connection Type Hardwire
Input Phase 3-Phase
BATTERY
Full Load Runtime (min.) 5.5 min. (16kw)
Half Load Runtime (min.) 13 min. (8kw)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
External Battery Pack Compatibility BP480V200; BP480V26B; BP480V300; BP480V400;BP480V40C; BP480V500
Expandable Runtime Description External battery pack wiring is contractor supplied
DC System Voltage (VDC) +/- 240VDC
Internal UPS Replacement Battery Cartridge SURBC2030
Battery Replacement Description Hot-swappable, replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
Undervoltage Correction Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye)
USER INTERFACE, ALERTS & CONTROLS
Switches ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more
LED Indicators 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise Suppression Yes
AC Suppression Joule Rating 5950
AC Suppression Response Time Instantaneous
PHYSICAL
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
UPS Power Module Dimensions (hwd, cm) 116.8 x 52.1 x 85.6
Maximum Device Depth (cm) 0
UPS Power Module Weight (kg) 267.2
UPS Shipping Dimensions (hwd / cm) 139.7 x 72.4 x 108
Shipping Weight (kg) 335.3
Cooling Method Fans
UPS Housing Material Steel
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 3053
COMMUNICATIONS
Communications Interface DB9 Serial; Slot for SNMP/Web interface
PowerAlert Software Included
Communications Cable DB9 cabling included
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power
High Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries
Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications CE
WARRANTY
Product Warranty Period (International) 2-year limited warranty
Product Warranty Period (Mexico) 1-year limited warranty
Product Warranty Period (Puerto Rico) 2-year limited warranty
Available models:
SU40KX 40kVA SmartOnline Modular 3-Phase UPS System. Includes 2 x 20kVA power modules and internal batteries.
SU60KX 60kVA SmartOnline Modular 3-Phase UPS System. Includes 3 x 20kVA power modules. Requires external battery cabinet.
SU60KX/26B 60kVA SmartOnline Modular 3-Phase UPS System, On-line Double-Conversion International UPS with Battery (BP480V26B).
SU80KX 80kVA SmartOnline Modular 3-Phase UPS System. Includes 4 x 20kVA power modules. Requires external battery cabinet.
SU80KX/40C 80kVA SmartOnline Modular 3-Phase UPS System, On-line Double-Conversion International UPS with Battery (BP480V40C).
SU80KX2 80kVA SmartOnline Modular 3-Phase UPS System, On-line Double-Conversion International UPS.
SU100KX2 100kVA SmartOnline Modular 3-Phase UPS System, On-line Double-Conversion International UPS.
SU120KX2 120kVA SmartOnline Modular 3-Phase UPS System, On-line Double-Conversion International UPS.
SU120KXNP Empty UPS Chassis for Tripp Lite SU80KX2, SU100KX2 and SU120KX2 UPS Systems.