OUTPUT
|
Output Volt Amp Capacity (VA) |
20000 |
Output kVA Capacity (kVA) |
20 |
Output Watt Capacity (Watts) |
16000 |
Output kW Capacity (kW) |
16 |
Power Factor |
0.8 |
Crest Factor |
3:1 |
Nominal Output Voltage(s) Supported |
220/380V; 230/400V; 240/415V; 3-Phase Wye |
Frequency Compatibility |
50 / 60 Hz |
Output Voltage Regulation (Line Mode) |
+/-1% |
Output Voltage Regulation (Battery Mode) |
+/-1% |
Output Receptacles |
Hardwire |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
Pure Sine wave |
|
INPUT
|
Rated input current (Maximum Load) |
28A / 29A / 30A |
Nominal Input Voltage(s) Supported |
220/380V (3ph wye); 230/400V (3ph wye); 240/415V (3ph wye) |
Nominal Input Voltage Description |
3-Phase Wye, 4 wire (L1, L2, L3, N, G) |
UPS Input Connection Type |
Hardwire |
Input Phase |
3-Phase |
|
BATTERY
|
Full Load Runtime (min.) |
5.5 min. (16kw) |
Half Load Runtime (min.) |
13 min. (8kw) |
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
External Battery Pack Compatibility |
BP480V200; BP480V26B; BP480V300; BP480V400;BP480V40C; BP480V500
|
Expandable Runtime Description |
External battery pack wiring is contractor supplied |
DC System Voltage (VDC) |
+/- 240VDC |
Internal UPS Replacement Battery Cartridge |
SURBC2030 |
Battery Replacement Description |
Hot-swappable, replaceable batteries |
Expandable Runtime |
Yes |
|
VOLTAGE REGULATION
|
Voltage Regulation Description |
Online, double-conversion power conditioning |
Overvoltage Correction |
Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal |
Undervoltage Correction |
Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye) |
|
USER INTERFACE, ALERTS & CONTROLS
|
Switches |
ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
Audible Alarm |
Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more |
LED Indicators |
4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions |
|
SURGE / NOISE SUPPRESSION
|
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Joule Rating |
5950 |
AC Suppression Response Time |
Instantaneous |
|
PHYSICAL
|
Installation Form Factors Supported with Included Accessories |
Tower |
Primary Form Factor |
Tower |
UPS Power Module Dimensions (hwd, cm) |
116.8 x 52.1 x 85.6 |
Maximum Device Depth (cm) |
0 |
UPS Power Module Weight (kg) |
267.2 |
UPS Shipping Dimensions (hwd / cm) |
139.7 x 72.4 x 108 |
Shipping Weight (kg) |
335.3 |
Cooling Method |
Fans |
UPS Housing Material |
Steel |
|
ENVIRONMENTAL
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
3053 |
|
COMMUNICATIONS
|
Communications Interface |
DB9 Serial; Slot for SNMP/Web interface |
PowerAlert Software |
Included |
Communications Cable |
DB9 cabling included |
|
LINE / BATTERY TRANSFER
|
Transfer Time |
No transfer time (0 ms.) in online, double-conversion mode |
Low Voltage Transfer to Battery Power (Setpoint) |
Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power |
High Voltage Transfer to Battery Power (Setpoint) |
Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power |
|
SPECIAL FEATURES
|
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
High Availability UPS Features |
Automatic inverter bypass; Hot swappable batteries |
Green Energy-Saving Features |
High efficiency economy mode operation; Schedulable daily hours of economy mode operation |
|
CERTIFICATIONS
|
|
WARRANTY
|
Product Warranty Period (International) |
2-year limited warranty |
Product Warranty Period (Mexico) |
1-year limited warranty |
Product Warranty Period (Puerto Rico) |
2-year limited warranty |
|