USER INTERFACE, ALERTS & CONTROLS
|
Reported Load Segments |
Supports monitoring of input current per phase (L1, L2, L3) and output current for 6 separately breakered load banks (B1-B6); Outlets are color-coded and labelled for easy phase and load bank identification; L1-N feeds black outlets (B1, B4); L2-N feeds dark-gray outlets (B2, B5); L3-N feeds light-gray outlets (B3, B6) |
Front Panel LCD Display |
Large 3-digit display reports Amperage, Kilowatts, Voltage, Unbalance percentage; Small 2-character display verifies the measurement the large display is reporting: Input-phase (L#), Load bank (B#), Load unbalance (UB), Output power (OP) |
Front Panel LEDs |
Set of 6 LEDs verify the value displayed on the large 3-digit display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB); One additional LED for each output load bank (B1-B6) offers information power availablity: GREEN (Power ON with <80% load), YELLOW (Power ON with >80% load), RED (Power OFF / undervoltage), RED FLASHING (Power OFF / breaker trip) |
Switches |
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power and Load balance options; Additional MODE button advances the LEDs to view available sub-options for each measurement category |
|
PHYSICAL
|
Shipping Dimensions (hwd / cm) |
194.5 x 15 x 17.5 |
Shipping Weight (kg) |
9.3 |
Unit Dimensions (hwd / cm) |
177.8 x 5.51 x 6.32 |
Unit Weight (kg) |
6.49 |
Material of Construction |
Metal |
Form Factors Supported |
Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks |
PDU Form Factor |
Vertical (0U) |
|
ENVIRONMENTAL
|
Operating Temperature Range |
32 to 122F (0 to 50C) |
Storage Temperature Range |
5 to 140F (-15 to 60C) |
Relative Humidity |
5-95% non-condensing |
Operating Elevation (m) |
0-3000 |
|
CERTIFICATIONS
|
Certifications |
Tested to CE (IEC 60950-1, EN55022, EN55024), EN Class A (Emissions), ROHS Compliant, TAA Compliant |
|
WARRANTY
|
Product Warranty Period (Worldwide) |
2-year limited warranty |
|
OVERVIEW
|
|
OUTPUT
|
Outlet Level Metering |
No |
Output Capacity Details |
23kW (415/240V), 22.2kW (400/230V), 21.1kW (380/220V), 20kW (360/200V) total capacity; 32A max per output phase (L1, L2, L3); 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet |
Frequency Compatibility |
50 / 60 Hz |
Output Receptacles |
(36) C13; (6) C19 |
Output Nominal Voltage |
220 (380V input); 230 (400V input) |
Overload Protection |
6 20A double-pole circuit breakers (2 per output phase) |
Outlet Type |
IEC-C13, IEC-C19 |
Individual Outlet Switching |
No |
|
INPUT
|
PDU Input Voltage |
380; 400 |
Maximum Input Amps |
32 |
PDU Plug Type |
IEC-309 32A RED (3P+N+E) |
Input Cord Length (m) |
1.83 |
Input Phase |
3-Phase |
|