PLEASE NOTE: All prices are exclusive of GST │ Please call / email our sales team to get the updated product price and to check the stock availability before placing an order. If you do not find the product that you require or the prices are not available ($0) please send us an email/ call us so we can assist. *Sold out products can be made available upon request.
Cart 0
TrippLite SMARTINT3000VS

TrippLite

TrippLite SMARTINT3000VS


SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

  • 3kVA / 3000VA / 2250W line interactive tower UPS system
  • 230V nominal output during brownouts to 151V and overvoltages to 282V
  • Extended runtime options, Front panel status LEDs
  • USB, RS232, EPO and optional SNMP/Web interface; 3 switched load banks
  • C20 inlet; 8 C13 & 1 C19 outlets; 3 C13 to C14 cables included

Features

  • SMARTINT3000VS line-interactive UPS offers protection from blackouts, brownouts, overvoltages and surges
  • 3000VA / 2250 watt capacity
  • Internal batteries support a half load of 1500VA for 14 minutes and a full load of 3000VA for 4 minutes
  • Runtime is further expandable with the addition of BP48V24-2U(limit 1), BP48V60RT-3U(multi-pack compatible) andBP48V27-2US(multi-pack compatible) external battery packs
  • Intelligent battery management system extends battery life
  • Maintains regulated 230V nominal output during brownouts and overvoltages from 151 to 282V
  • Includes 9 UPS supported outlets with 3 individually controllable load banks(2 outlets per bank) that can be powered off and back on again via software interface
  • IEC320-C20 input connection accepts a variety of detachable cord sets to match country or site-specific wall receptacles
  • PowerAlert UPS monitoring and unattended shutdown software included
  • Offers simultaneous monitoring by up to 4 directly-connected devices through included USB and DB9 interface ports, or the monitoring by any number of additional servers over IP with included PowerAlert monitoring software
  • Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity
  • Emergency Power Off(EPO) interface with cable
  • Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for delayed or immediate reboot of connected devices
  • Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
  • Supports Tripp Lite's WatchDog software application(requires optional WATCHDOGSW)
  • Built-in accessory slot supports SNMP with optionalSNMPWEBCARD adapter
  • Emergency Power Off(EPO) interface with cable
  • Multi-function audible alarms and set of 5 front panel LEDs
  • Network-grade AC surge suppression

Specifications

OUTPUT
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2250
Output kW Capacity (kW) 2.25
Output Capacity Details 2250W maximum with up to 1 external battery pack; 1500W maximum with 2 or more external battery packs
Power Factor 0.75
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details 230v nominal inverter output voltage
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode) -19% +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Output Receptacles (8) C13; (1) C19
Included Output Power Cables Includes 3 C13 to C14 output power cables
Load Management Receptacles Three switchable two-outlet C13 load banks
Output Circuit Breakers 10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
INPUT
Rated input current (Maximum Load) 15.4A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C20 inlet
UPS Input Connection Description User supplies input cabling with C19 output connection
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4 min. (2250w)
Half Load Runtime (min.) 14 min. (1125w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge RBC54
Battery Access Battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V
Overvoltage Correction Input voltages between 245 and 282 are reduced by 12%
Undervoltage Correction Input voltages between 177 and 199 are boosted by 14%
Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 480
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Tower
UPS Power Module Dimensions (hwd, cm) 36.2 x 23.5 x 30.5
UPS Power Module Weight (kg) 27.7
UPS Shipping Dimensions (hwd / cm) 40.6 x 37.5 x 50.2
Shipping Weight (kg) 30.6
Cooling Method Fan
UPS Housing Material Polycarbonate
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 488.3
AC Mode Efficiency Rating (100% Load) 94%
Audible Noise Audible Noise < 47dBA At Front Side 1 Meter
COMMUNICATIONS
Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software Included
Communications Cable 2 USB and 2 DB9 cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 151
High Voltage Transfer to Battery Power (Setpoint) 282
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries
Green Energy-Saving Features Individually controllable load banks
CERTIFICATIONS
UPS Certifications CE
UPS Certification Details CE 62040
WARRANTY
Product Warranty Period (International) 2-year limited warranty
Product Warranty Period (Mexico) 2-year limited warranty